Products / Tensorpack T
TENSORPACK · T

Tensorpack T

C&I · Microgrid

Rated power
50–130 kW
Energy
217 / 241 / 265 kWh
Cooling
Air-cooled
Voltage
400 V
Tensorpack T

Models & Specifications

All Tensorpack T variants share the same platform — 400 V, air-cooled, 15-year warranty, outdoor cabinet, IEC · UL · CE. Power and energy vary by model.

AC coupled

AC-coupled — a grid-tied PCS for storage-only systems. Off-grid operation is possible but requires an added controller.

AC-coupled cabinet
ModelRated powerEnergy
Tensorpack T-B217-G100 100 kW217 kWh
Tensorpack T-B241-G100 100 kW241 kWh
Tensorpack T-B265-G100 100 kW265 kWh
Tensorpack T-B434-G100 100 kW434 kWh
Tensorpack T-B482-G100 100 kW482 kWh
Tensorpack T-B530-G100 100 kW530 kWh
Tensorpack T-B265-G130 130 kW265 kWh
Tensorpack T-B434-G130 130 kW434 kWh
Tensorpack T-B482-G130 130 kW482 kWh
Tensorpack T-B530-G130 130 kW530 kWh
DC coupled

DC-coupled — a hybrid PCS that also accepts PV and a diesel generator, with an integrated STS for on-/off-grid transfer and off-grid operation.

DC-coupled cabinet
ModelRated powerEnergy
Tensorpack T-B120-H50 50 kW120 kWh
Tensorpack T-B217-H50 50 kW217 kWh
Tensorpack T-B241-H50 50 kW241 kWh
Tensorpack T-B217-H100 100 kW217 kWh
Tensorpack T-B241-H100 100 kW241 kWh
Tensorpack T-B265-H100 100 kW265 kWh
Tensorpack T-B265-H125 125 kW265 kWh

Battery certification

Product & safety certification to international standards — recognised across markets outside North America and Japan.

IEC 62619IEC 63056IEC 62477-1IEC 60730-1 Annex HIEC 61000-6-2 / -4UL 9540ACEUN 38.3RoHSREACH

Available in

🇦🇺Australia🇧🇷Brazil🇨🇱Chile🇨🇳China🇪🇺EU🇳🇿New Zealand🇳🇴Norway🇨🇭Switzerland🇺🇦Ukraine🇬🇧UK

PCS grid certification

Certified for the grid — worldwide. Inverter / PCS interconnection compliance across 21 markets.

🇪🇺EUEN 50549-1/-2/-10
🇦🇺AustraliaAS 4777 · CEC
🇦🇹AustriaTOR
🇧🇪BelgiumC10 / C11 Type B
🇨🇿CzechiaPPDS
🇩🇰DenmarkTF 3.3.1
🇫🇮FinlandSFS EN 50549
🇫🇷FranceUTE C15-712-1
🇩🇪GermanyVDE-AR-N 4105 / 4110
🇭🇺HungaryDSO · EN 50549
🇮🇹ItalyCEI 0-21 · 0-16
🇳🇱NetherlandsEN 50549
🇳🇴NorwayRENBlad 342
🇵🇱PolandEN 50549
🇵🇹PortugalEN 50549 · Ord. 73/2020
🇷🇴RomaniaOrder no. 3
🇸🇰SlovakiaSTN EN 50549
🇪🇸SpainNTS 2.1 · UNE 217002
🇸🇪SwedenEIFS 2018:2
🇨🇭SwitzerlandNA/EEA NE7 · NE3-5
🇬🇧UKG99 · ENA

Safety by Design

From the cell to the cabinet, multiple independent systems watch, isolate and contain faults — backed by international product and environmental certification.

01

Cell

Per-cell voltage and temperature monitoring, balancing, and over- / under-voltage and over-temperature protection.

02

Pack

Over-current and short-circuit protection, temperature and insulation monitoring, and module-level disconnection.

03

System

DC + AC breakers, coordinated BMS / EMS trip, emergency stop, and earth-fault / leakage protection.

Fire suppression & protection
🧯
Aerosol

Per-cabinet aerosol suppression that releases on a confirmed fire signal.

💧
Water fire suppression

System-level water suppression that can connect to an external fire hydrant.

🛡️
Explosion-proof design

Explosion-proof enclosure that contains and safely vents pressure.

💨
Explosion-proof exhaust fan

Explosion-proof ventilation that clears flammable gas build-up.

🚨
Fire control host

Central fire alarm unit that can link into the customer's building fire system.

📟
Detection

CW1310-07A multi-gas detector plus heat-sensitive cable for cabinet-level sensing.

Other models